Zaber Technologies Logo

  • 75, 150, 300, 450, 600 mm travel
  • Up to 10 µm accuracy over 600 mm travel
  • Up to 270 mm/s speed and up to 500 N thrust
  • 100 kg load capacity
  • Inline and parallel drive configurations
  • Ball screw and lead screw configurations
  • Integrated linear encoders with 50 nm resolution provide slip/stall detection and position correction
  • Designed for use with an X-MCC Series stepper motor controller or any 2-phase stepper motor controller
  • With Auto Detect, the X-MCC controller configures its settings automatically for the connected peripheral
  • Custom versions available

Features:

1. Integrated linear encoder with 50 nm resolution and stage calibration provides full travel accuracy up to 10 µm.
2. Inline and parallel drive configurations.
3. Lead screw and ball screw configurations.
4. Stage top supports Metric M3 and M6 threaded holes.
5. Travel lengths from 75 to 600 mm, with custom lengths available.
6. 200 step per revolution stepper motor.
7. LRQ-DE stages can be assembled in XY or XYZ configuration with an AB104 angle bracket.
8. Panel Mount DB26 with Auto Detect allows the stage to be easily connected to an X-MCC series controller and ready to use without additional user input.

Zaber Technologies’ LRQ-DE Series products are computer-controlled, motorized linear stages with high stiffness, load, and lifetime capabilities in a compact size. An integrated linear encoder combined with stage calibration provides high accuracy positioning over the full travel of the device. At only 36 mm high, these stages are excellent for applications where a low profile is required. These stages are capable of speeds up to 270 mm/s, and can bolt together into XY and XYZ systems. Some multi axis configurations may require additional accessories, please contact Zaber Technologies Technical Support to ensure the correct ones are selected. Each device is available in either an inline or parallel drive configuration.

The stages are designed to connect directly to our X-MCC Series universal motor controllers, or they can be used with any 2-phase stepper motor controller through the panel mount DB26 connector. Set up is easy with Auto Detect. Once connected, the X-MCC controller will automatically detect and configure the LRQ-DE.

 

 

 

Axes of Motion

1

Built-in Controller

No

CE Compliant

Yes

Default Resolution

1/64 of a step

Guide Type

Recirculating Ball Linear Guide

Inductance

2.2 mH/phase

Limit or Home Sensing

Magnetic home sensor

Maximum Centered Load

1000 N

Motor Connection

D-sub 26

Motor Rated Current

2300 mA/phase

Motor Steps Per Rev

200

Motor type

Stepper (2 phase)

Mounting Interface

M6 and M3 threaded holes

Operating Temperature

0 – 50 °C

RoHS Compliant

Yes

Travel Range

75 mm, 150 mm, 300 mm, 450 mm, 600 mm

Vacuum Compatible

No

Encoder Resolution

50 nm

Encoder Type

Linear quadrature encoder

Lifetime Factor A

-523.44

Lifetime Factor B

7462.88

Motor Winding Resistance

1

LRQ075AL-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.025 °
  • Repeatability: < 2.5 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000061 mm/s
  • Travel Range: 75 mm
  • Vertical Runout: < 20 µm
  • Weight: 2.25 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.02 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ075AL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075AL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 75 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 2.25 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ075AP-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.025 °
  • Repeatability: < 2.5 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000061 mm/s
  • Vertical Runout: < 20 µm
  • Weight: 2.41 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.02 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ075AP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075AP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 75 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 2.41 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ075BL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.025 °
  • Repeatability: < 3.5 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 20 µm
  • Weight: 2.25 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.02 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 100 N

LRQ075BL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075BL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 75 mm travel, integrated linear encoder, medium resolution, medium speed, inline drive, with Auto Detect 2.25 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ075BP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.025 °
  • Repeatability: < 3.5 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 20 µm
  • Weight: 2.41 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.02 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 100 N

LRQ075BP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075BP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 75 mm travel, integrated linear encoder, medium resolution, medium speed, parallel drive, with Auto Detect 2.41 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ075HL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.025 °
  • Repeatability: < 3 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 20 µm
  • Weight: 2.25 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.02 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 200 N

LRQ075HL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075HL-DE51T10A 1 Motorized, ball-screw driven, linear stage, 75 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 2.25 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ075HP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.025 °
  • Repeatability: < 3 µm
  • Roll: 0.01 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 20 µm
  • Weight: 2.41 kg
  • X – Travel Range: 75 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.02 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 200 N

LRQ075HP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ075HP-DE51T10A 1 Motorized, ball-screw driven, linear stage, 75 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 2.41 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150AL-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.03 °
  • Repeatability: < 2.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000061 mm/s
  • Travel Range: 150 mm
  • Vertical Runout: < 25 µm
  • Weight: 2.64 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.02 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ150AL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150AL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 150 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 2.64 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150AP-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.03 °
  • Repeatability: < 2.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000061 mm/s
  • Vertical Runout: < 25 µm
  • Weight: 2.80 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.02 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ150AP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150AP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 150 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 2.80 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150BL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.03 °
  • Repeatability: < 3.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 25 µm
  • Weight: 2.64 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.02 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 100 N

LRQ150BL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150BL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 150 mm travel, integrated linear encoder, medium resolution, medium speed, inline drive, with Auto Detect 2.64 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150BP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.03 °
  • Repeatability: < 3.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 25 µm
  • Weight: 2.80 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.02 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 100 N

LRQ150BP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150BP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 150 mm travel, integrated linear encoder, medium resolution, medium speed, parallel drive, with Auto Detect 2.80 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150HL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.03 °
  • Repeatability: < 3 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 25 µm
  • Weight: 2.64 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.02 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 200 N

LRQ150HL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150HL-DE51T10A 1 Motorized, ball-screw driven, linear stage, 150 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 2.64 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ150HP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 20 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.03 °
  • Repeatability: < 3 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 25 µm
  • Weight: 2.80 kg
  • X – Travel Range: 150 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.02 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 200 N

LRQ150HP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ150HP-DE51T10A 1 Motorized, ball-screw driven, linear stage, 150 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 2.80 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300AL-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.034 °
  • Repeatability: < 2.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000061 mm/s
  • Travel Range: 300 mm
  • Vertical Runout: < 35 µm
  • Weight: 3.44 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.03 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ300AL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300AL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 300 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 3.44 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300AP-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.034 °
  • Repeatability: < 2.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000061 mm/s
  • Vertical Runout: < 35 µm
  • Weight: 3.60 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.03 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ300AP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300AP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 300 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 3.60 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300BL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.034 °
  • Repeatability: < 3.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 35 µm
  • Weight: 3.44 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.03 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 100 N

LRQ300BL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300BL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 300 mm travel, integrated linear encoder, medium resolution, medium speed, inline drive, with Auto Detect 3.44 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300BP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.034 °
  • Repeatability: < 3.5 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 35 µm
  • Weight: 3.60 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.03 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 100 N

LRQ300BP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300BP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 300 mm travel, integrated linear encoder, medium resolution, medium speed, parallel drive, with Auto Detect 3.60 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300HL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.034 °
  • Repeatability: < 3 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 35 µm
  • Weight: 3.44 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.03 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 200 N

LRQ300HL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300HL-DE51T10A 1 Motorized, ball-screw driven, linear stage, 300 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 3.44 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ300HP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 30 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.034 °
  • Repeatability: < 3 µm
  • Roll: 0.015 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 35 µm
  • Weight: 3.60 kg
  • X – Travel Range: 300 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.03 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 200 N

LRQ300HP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ300HP-DE51T10A 1 Motorized, ball-screw driven, linear stage, 300 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 3.60 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450AL-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.04 °
  • Repeatability: < 2.5 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000061 mm/s
  • Travel Range: 450 mm
  • Vertical Runout: < 45 µm
  • Weight: 4.23 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.04 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ450AL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450AL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 450 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 4.23 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450AP-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.04 °
  • Repeatability: < 2.5 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000061 mm/s
  • Vertical Runout: < 45 µm
  • Weight: 4.39 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.04 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ450AP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450AP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 450 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 4.39 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450BL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.04 °
  • Repeatability: < 3.5 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 45 µm
  • Weight: 4.23 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.04 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 100 N

LRQ450BL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450BL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 450 mm travel, integrated linear encoder, medium resolution, medium speed, inline drive, with Auto Detect 4.23 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450BP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.04 °
  • Repeatability: < 3.5 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 45 µm
  • Weight: 4.39 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.04 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 100 N

LRQ450BP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450BP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 450 mm travel, integrated linear encoder, medium resolution, medium speed, parallel drive, with Auto Detect 4.39 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450HL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.04 °
  • Repeatability: < 3 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 45 µm
  • Weight: 4.23 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.04 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 200 N

LRQ450HL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450HL-DE51T10A 1 Motorized, ball-screw driven, linear stage, 450 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 4.23 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ450HP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 40 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.04 °
  • Repeatability: < 3 µm
  • Roll: 0.025 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 45 µm
  • Weight: 4.39 kg
  • X – Travel Range: 450 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.04 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 200 N

LRQ450HP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ450HP-DE51T10A 1 Motorized, ball-screw driven, linear stage, 450 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 4.39 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600AL-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.045 °
  • Repeatability: < 2.5 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000061 mm/s
  • Travel Range: 600 mm
  • Vertical Runout: < 75 µm
  • Weight: 4.98 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.04 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ600AL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600AL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 600 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 4.98 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600AP-DE51T10A-MC10

  • Accuracy (unidirectional): 10 µm
  • Backlash: < 5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 1.27
  • Maximum Speed: 54 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.09921875
  • Minimum Speed: 0.000061 mm/s
  • Peak Thrust: 230 N
  • Pitch: 0.045 °
  • Repeatability: < 2.5 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000061 mm/s
  • Vertical Runout: < 75 µm
  • Weight: 5.14 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: fine resolution
  • Yaw: 0.04 °
  • Back-driving Force: Non-back-driving
  • Maximum Continuous Thrust: 100 N

LRQ600AP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600AP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 600 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 5.14 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600BL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.045 °
  • Repeatability: < 3.5 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 75 µm
  • Weight: 4.98 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.04 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 100 N

LRQ600BL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600BL-DE51T10A 1 Motorized, lead-screw driven, linear stage, 600 mm travel, integrated linear encoder, medium resolution, medium speed, inline drive, with Auto Detect 4.98 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600BP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 6.35
  • Maximum Speed: 270 mm/s
  • Mechanical Drive System: Precision lead screw
  • Microstep Size (Default Resolution): 0.49609375
  • Minimum Speed: 0.000303 mm/s
  • Peak Thrust: 150 N
  • Pitch: 0.045 °
  • Repeatability: < 3.5 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000303 mm/s
  • Vertical Runout: < 75 µm
  • Weight: 5.14 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: medium resolution
  • Yaw: 0.04 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 100 N

LRQ600BP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600BP-DE51T10A 1 Motorized, lead-screw driven, linear stage, 600 mm travel, integrated linear encoder, medium resolution, medium speed, parallel drive, with Auto Detect 5.14 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600HL-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.045 °
  • Repeatability: < 3 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 75 µm
  • Weight: 4.98 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.04 °
  • Back-driving Force: 93 N
  • Maximum Continuous Thrust: 200 N

LRQ600HL-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600HL-DE51T10A 1 Motorized, ball-screw driven, linear stage, 600 mm travel, integrated linear encoder, fine resolution, low speed, inline drive, with Auto Detect 4.98 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg

LRQ600HP-DE51T10A-MC10

  • Accuracy (unidirectional): 13 µm
  • Backlash: < 6.5 µm
  • Horizontal Runout: < 60 µm
  • Linear Motion Per Motor Rev: 2.5
  • Maximum Speed: 110 mm/s
  • Mechanical Drive System: Precision ball screw
  • Microstep Size (Default Resolution): 0.1953125
  • Minimum Speed: 0.000119 mm/s
  • Peak Thrust: 500 N
  • Pitch: 0.045 °
  • Repeatability: < 3 µm
  • Roll: 0.035 °
  • Speed Resolution: 0.000119 mm/s
  • Vertical Runout: < 75 µm
  • Weight: 5.14 kg
  • X – Travel Range: 600 mm travel
  • Y – Resolution Level: medium resolution, ball-screw driven
  • Yaw: 0.04 °
  • Back-driving Force: 123 N
  • Maximum Continuous Thrust: 200 N

LRQ600HP-DE51T10A-MC10 is a kit, comprised of:

Product Code Qty Description Weight
LRQ600HP-DE51T10A 1 Motorized, ball-screw driven, linear stage, 600 mm travel, integrated linear encoder, fine resolution, low speed, parallel drive, with Auto Detect 5.14 kg
MC10 1 Motor extension cable, 1.5 m, for use with X-MCC Series controllers and T10A peripherals 0.286 kg
Zaber-CE-Declaration-of-Conformity-Machinery
Zaber-CE-Declaration-of-Conformity-EMC
Getting-started-guide
BACK
TO TOP

Request a Demo

LRQ-DE Series

Ask the Expert

If you’re interested in the products shown here, or have questions about something you can’t find on our website, please get in touch through the form below.

Our knowledgeable sales team will be happy to help. We can normally source exactly what you need, or work with you to come up with custom solutions.

Alternatively, just call +44 (0) 1933 461 666 and ask to speak to the Photonics team.